FIRE PROTECTION SYSTEMS IN ASIA PACIFIC

Can fire protection and low-voltage electrical systems share the same cable tray

Can fire protection and low-voltage electrical systems share the same cable tray

Sharing the same cable tray or conduit with data cables increases the risk of mechanical damage and impairs fire resistance. While all data cable is ran within cable tray, about 20% or so of the fire alarm cable is sharing the same tray. Power-Limited Fire Alarm (PLFA) circuits, which make up the majority of modern fire alarm systems, are generally permitted by the NEC to share a cable tray or raceway with communications circuits, provided certain conditions are met. Poor segregation, inadequate fire resistance, or unsuitable fixings can compromise both system performance and occupant safety. YY, SY and CY cables are made to various manufacturers specifications but not governed by any National, European or International standard, hence these are not currently recognized in BS 7671:2018, Regulation 133. 1 of BS 7671:2018 requires every item of equipment to comply with the appropriate.

Read More
How to coordinate relay protection systems

How to coordinate relay protection systems

Relay coordination refers to setting protective devices so that the relay closest to the fault operates first, while upstream relays act as backups. Relay coordination is one of the most critical aspects of electrical power system protection. As electric power generation facilities grow in complexity, ensuring proper relay settings becomes increasingly challenging.

Read More
How to strengthen the protection of communication optical cables

How to strengthen the protection of communication optical cables

To protect fiber optic cables and ensure their optimal performance, you need to follow some best practices in installation, maintenance, and testing. In this article, you will learn about some of the most effective ways to protect fiber optic cables from common threats and. They connect optical modules between switches and servers, appear in AOC cables, link racks inside data centers, and are also used to. However, they are also vulnerable to physical damage, environmental factors, and signal degradation.

Read More
Microcomputer Relay Protection Debugging Tools

Microcomputer Relay Protection Debugging Tools

Selection of Test InstrumentsThe main test instruments for microcomputer protection devices are: microcomputer relay protection tester, three-phase current generator, and multimeter. Megger's advanced relay software simplifies protection testing with built-in routines for digital and electromechanical relays from global manufacturers. Automate test plans, reduce errors, and boost productivity—whether in the lab or out in the field. TEST-750 single phase relay test set is a portable relay test unit, high performance, operation simply, portable designed to test in the field; It adopts aluminum alloy body with PC panel, robust shape; Microcomputer with the 32bit ARM chip control, LCD screen display single-phase protective relay. Test-330 three phase microcomputer protection relay test equipment is the highly efficient relay tester of our company.

Read More
Polarity of current transformers used in relay protection

Polarity of current transformers used in relay protection

The ANSI/IEEE standard for transformers states that the high voltage should lead the low voltage by 30° with wye–delta or delta–wye banks. Polarity is very important for the operation of transformers and protection equipment. How are current transformers used in protection systems for power grids and substations? Current transformers (CTs) are the primary sensing interfaces between high-current power circuits and the low-voltage protection and metering equipment used in substations and transmission networks. One of the most critical aspects of using CTs in these systems is ensuring correct CT polarity for differential protection.

Read More