Network ping to aggregation switch has latency

Network ping to aggregation switch has latency

We recommend to check the latency by doing ping test between end devices/hosts, instead of doing a ping test to switch IP. A Socket deployment using Link Aggregation (LAG) with an internal switch may experience high latency and packet loss if the link isn't configured correctly. You can use a LAG to directly connect two switches when the traffic between them.

Read More
CRC Issues with Optical Modules

CRC Issues with Optical Modules

Typically they are caused by either defective cable, transceiver (SFP), switch port, upstream network device, etc. This article describes steps to perform to troubleshoot an Optical Transceiver CRC issueCRC errors can be caused by a number of factors. Common technologies for the error detection include parity check, checksum, and cyclic redundancy check (CRC). one pair is working perfectly, the other got thousands of 46920 input errors, 42586 CRC. and the switch's log shown %SFF8472-5-THRESHOLD_VIOLATION: Te1/1/2: Rx power low alarm; Operating value: -20. Cyclic Redundancy Check (CRC) alignment errors or CRC/Align errors occur in digital networks during the process of error detection.

Read More
ESD Issues with Optical Modules

ESD Issues with Optical Modules

Two main approaches are available to effectively prevent optical module failures: ESD prevention and physical protection. What Are the Main Causes for and Protection Measures Against Optical Module Failures? - CloudEngine 16800, 12800, 9800, 8800, 7800, 6800, and 5800 Series Switches Troubleshooting Guide (V100 and V200) - Huawei What Are the Main Causes for and Protection Measures Against Optical Module Failures?Optical modules must be handled with standardized procedures during application, as any non-compliant action may cause potential damage or permanent failure. An optical module is a critical component in modern optical communication systems, directly affecting transmission stability, network reliability, and operational efficiency. This document provides guidelines that will help you reduce the risk of electrostatic discharge (ESD) or electrical overvoltage stress (EOS) damage to your sampling modules. Learn the most common causes of optical transceiver failures in AI clusters and high-speed data centers, including ESD damage, port contamination, compatibility issues, overheating, and component aging.

Read More
Distribution box incoming and outgoing line issues

Distribution box incoming and outgoing line issues

Check the electrical load and ensure that the sensors do not exceed the 10 Amp maximum. Lightning Protection Limited by Installing Surge Arresters Only on the Incoming Line Side Typically, fuses or other devices are installed between the incoming/outgoing lines and the busbar inside the distribution box. The utility model discloses a power distribution box incoming and outgoing line structure. However, in actual applications, distribution boxes often encounter a series of problems, which not only affect the normal operation of the power system, but also may bring safety hazards.